104 research outputs found

    p, He, and C to Fe cosmic-ray primary fluxes in diffusion models: Source and transport signatures on fluxes and ratios

    Full text link
    The propagated fluxes of proton, helium, and heavier primary cosmic-ray species (up to Fe) are a means to indirectly access the source spectrum of cosmic rays. We check the compatibility of the primary fluxes with the transport parameters derived from the B/C analysis, but also if they bring further constraints. Proton data are well described in the simplest model defined by a power-law source spectrum and plain diffusion. They can also be accommodated by models with, e.g., convection and/or reacceleration. There is no need for breaks in the source spectral indices below 1\sim 1 TeV/n. Fits on the primary fluxes alone do not provide physical constraints on the transport parameters. If we let free the source spectrum dQ/dE=qβηSRαdQ/dE = q \beta^{\eta_S} {\cal R}^{-\alpha} and fix the diffusion coefficient K(R)=K0βηTRδK(R)= K_0\beta^{\eta_T} {\cal R}^{\delta} such as to reproduce the B/C ratio, the MCMC analysis constrains the source spectral index α\alpha to be in the range 2.22.52.2-2.5 for all primary species up to Fe, regardless of the value of the diffusion slope δ\delta. The ηS\eta_S low-energy shape of the source spectrum is degenerate with the low-energy shape ηT\eta_T of the diffusion coefficient: we find ηSηT0\eta_S-\eta_T\approx 0 for p and He data, but ηSηT1\eta_S-\eta_T\approx 1 for C to Fe primary species. This is consistent with the toy-model calculation in which the shape of the p/He and C/O to Fe/O data is reproduced if ηSηT01\eta_S-\eta_T\approx 0-1 (no need for different slopes α\alpha). When plotted as a function of the kinetic energy per nucleon, the low-energy p/He ratio is shaped mostly by the modulation effect, whereas primary/O ratios are mostly shaped by their destruction rate.Comment: 18 pages, 14 figures: accepted in A&A (1 table added

    Pippi - painless parsing, post-processing and plotting of posterior and likelihood samples

    Full text link
    Interpreting samples from likelihood or posterior probability density functions is rarely as straightforward as it seems it should be. Producing publication-quality graphics of these distributions is often similarly painful. In this short note I describe pippi, a simple, publicly-available package for parsing and post-processing such samples, as well as generating high-quality PDF graphics of the results. Pippi is easily and extensively configurable and customisable, both in its options for parsing and post-processing samples, and in the visual aspects of the figures it produces. I illustrate some of these using an existing supersymmetric global fit, performed in the context of a gamma-ray search for dark matter. Pippi can be downloaded and followed at http://github.com/patscott/pippi .Comment: 4 pages, 1 figure. v3: Updated for pippi 2.0. New features include hdf5 support, out-of-core processing, inline post-processing with arbitrary Python code in the input file, and observable-specific data cuts. Pippi can be downloaded from http://github.com/patscott/pipp

    Cosmic-ray antiproton constraints on light dark matter candidates

    Full text link
    Some direct detection experiments have recently collected excess events that could be interpreted as a dark matter (DM) signal, pointing to particles in the \sim10 GeV mass range. We show that scenarios in which DM can self-annihilate with significant couplings to quarks are likely excluded by the cosmic-ray (CR) antiproton data, provided the annihilation is S-wave dominated when DM decouples in the early universe. These limits apply to most of supersymmetric candidates, eg in the minimal supersymmetric standard model (MSSM) and in the next-to-MSSM (NMSSM), and more generally to any thermal DM particle with hadronizing annihilation final states.Comment: Contribution to the proceedings of TAUP-2011 (Munich, 5-9 IX 2011). 4 page

    I-care-an interaction system for the individual activation of people with dementia

    Get PDF
    I-CARE is a hand-held activation system that allows professional and informal caregivers to cognitively and socially activate people with dementia in joint activation sessions without special training or expertise. I-CARE consists of an easy-to-use tablet application that presents activation content and a server-based backend system that securely manages the contents and events of activation sessions. It tracks various sources of explicit and implicit feedback from user interactions and different sensors to estimate which content is successful in activating individual users. Over the course of use, I-CARE’s recommendation system learns about the individual needs and resources of its users and automatically personalizes the activation content. In addition, information about past sessions can be retrieved such that activations seamlessly build on previous sessions while eligible stakeholders are informed about the current state of care and daily form of their protegees. In addition, caregivers can connect with supervisors and professionals through the I-CARE remote calling feature, to get activation sessions tracked in real time via audio and video support. In this way, I-CARE provides technical support for a decentralized and spontaneous formation of ad hoc activation groups and fosters tight engagement of the social network and caring community. By these means, I-CARE promotes new care infrastructures in the community and the neighborhood as well as relieves professional and informal caregivers

    Status of cosmic-ray antideuteron searches

    Full text link
    The precise measurement of cosmic-ray antiparticles serves as important means for identifying the nature of dark matter. Recent years showed that identifying the nature of dark matter with cosmic-ray positrons and higher energy antiprotons is difficult, and has lead to a significantly increased interest in cosmic-ray antideuteron searches. Antideuterons may also be generated in dark matter annihilations or decays, offering a potential breakthrough in unexplored phase space for dark matter. Low-energy antideuterons are an important approach because the flux from dark matter interactions exceeds the background flux by more than two orders of magnitude in the low-energy range for a wide variety of models. This review is based on the "dbar14 - dedicated cosmic-ray antideuteron workshop", which brought together theorists and experimentalists in the field to discuss the current status, perspectives, and challenges for cosmic-ray antideuteron searches and discusses the motivation for antideuteron searches, the theoretical and experimental uncertainties of antideuteron production and propagation in our Galaxy, as well as give an experimental cosmic-ray antideuteron search status update. This report is a condensed summary of the article "Review of the theoretical and experimental status of dark matter identification with cosmic-ray antideuteron" (arXiv:1505.07785).Comment: 9 pages, 4 figures, ICRC 2015 proceeding

    Hybrid fNIRS-EEG based classification of auditory and visual perception processes

    Get PDF
    For multimodal Human-Computer Interaction (HCI), it is very useful to identify the modalities on which the user is currently processing information. This would enable a system to select complementary output modalities to reduce the user\u27s workload. In this paper, we develop a hybrid Brain-Computer Interface (BCI) which uses Electroencephalography (EEG) and functional Near Infrared Spectroscopy (fNIRS) to discriminate and detect visual and auditory stimulus processing. We describe the experimental setup we used for collection of our data corpus with 12 subjects. On this data, we performed cross-validation evaluation, of which we report accuracy for different classification conditions. The results show that the subject-dependent systems achieved a classification accuracy of 97.8% for discriminating visual and auditory perception processes from each other and a classification accuracy of up to 94.8% for detecting modality-specific processes independently of other cognitive activity. The same classification conditions could also be discriminated in a subject-independent fashion with accuracy of up to 94.6 and 86.7%, respectively. We also look at the contributions of the two signal types and show that the fusion of classifiers using different features significantly increases accuracy

    Design and construction of a Cherenkov imager for charge measurement of nuclear cosmic rays

    Full text link
    A proximity focusing Cherenkov imager called CHERCAM, has been built for the charge measurement of nuclear cosmic rays with the CREAM instrument. It consists of a silica aerogel radiator plane across from a detector plane equipped with 1,600 1" diameter photomultipliers. The two planes are separated by a ring expansion gap. The Cherenkov light yield is proportional to the charge squared of the incident particle. The expected relative light collection accuracy is in the few percents range. It leads to an expected single element separation over the range of nuclear charge Z of main interest 1 < Z < 26. CHERCAM is designed to fly with the CREAM balloon experiment. The design of the instrument and the implemented technical solutions allowing its safe operation in high altitude conditions (radiations, low pressure, cold) are presented.Comment: 24 pages, 19 figure

    The AMS-RICH velocity and charge reconstruction

    Full text link
    The AMS detector, to be installed on the International Space Station, includes a Ring Imaging Cerenkov detector with two different radiators, silica aerogel (n=1.05) and sodium fluoride (n=1.334). This detector is designed to provide very precise measurements of velocity and electric charge in a wide range of cosmic nuclei energies and atomic numbers. The detector geometry, in particular the presence of a reflector for acceptance purposes, leads to complex Cerenkov patterns detected in a pixelized photomultiplier matrix. The results of different reconstruction methods applied to test beam data as well as to simulated samples are presented. To ensure nominal performances throughout the flight, several detector parameters have to be carefully monitored. The algorithms developed to fulfill these requirements are presented. The velocity and charge measurements provided by the RICH detector endow the AMS spectrometer with precise particle identification capabilities in a wide energy range. The expected performances on light isotope separation are discussed.Comment: Contribution to the ICRC07, Merida, Mexico (2007); Presenter: F. Bara

    The RICH detector of the AMS-02 experiment: status and physics prospects

    Full text link
    The Alpha Magnetic Spectrometer (AMS), whose final version AMS-02 is to be installed on the International Space Station (ISS) for at least 3 years, is a detector designed to measure charged cosmic ray spectra with energies up to the TeV region and with high energy photon detection capability up to a few hundred GeV. It is equipped with several subsystems, one of which is a proximity focusing RICH detector with a dual radiator (aerogel+NaF) that provides reliable measurements for particle velocity and charge. The assembly and testing of the AMS RICH is currently being finished and the full AMS detector is expected to be ready by the end of 2008. The RICH detector of AMS-02 is presented. Physics prospects are briefly discussed.Comment: 5 pages. Contribution to the 10th ICATPP Conference on Astroparticle, Particle, Space Physics, Detectors and Medical Physics Applications (Como 2007). Presenter: Rui Pereir
    corecore